Sale!

SPU50-30 50,000 BTU 30' Total Emitter Tube Length 'U' Shaped

Original price was: $1,463.00.Current price is: $1,341.20.

SPU50-30 50,000 BTU 30' Total Emitter Tube Length 'U' Shaped - Min mounting height at horizontal of 11  FT

Usually ships in 5-8 Days

Product Add-Ons

SKU: SPU50-30 Categories: ,

Description

SPU Series - For Commercial/Industrial Use Only

The Economical Alternative for Hard-to-Heat Spaces

Whether you need to heat your warehouse, garage, or other hard-to-heat spaces, the SunStar SPS/U Series infrared heaters provide both the field efficiency of radiant heat and the installation flexibility you need…and all at a comfortable price.

  • Push Through System
  • 8 different Btu sizes and more than 60 different configurations to custom design your infrared heating system
  • CSA design certified
  • Available in natural and propane gas
  • Optional elbows and corner reflectors
  • Optional decorative grille
  • Sidewall or through the roof venting
  • Vented or indirect vented operation
  • Includes 36″ stainless steel gas connector

 

Introducing TISS™ Tube Integrity Safety Shut-Off System

TISS™ Tube Integrity Safety Shut-Off SystemSunStar’s patent pending innovative safety feature for positive pressure radiant tube heaters is called the “Tube Integrity Safety System” (TISS™).

In the unlikely event of a tube failure, TISS™ has been designed to automatically shut off the heater. The revolutionary TISS™ uses a simple principle to place an electrically insulated aluminum wire in tension above the reflector. Low voltage is then continuously passed along the wire in line with the gas control circuit. If heat levels increase due to heat exchanger failure, the wire melts and the safety circuit is broken, breaking the 24 volt circuit and shutting down the heater.

You may never know it is there, but it provides peace of mind.

SPU Dimensions

Model Total Tube Length Overall Dimensions "L" (FT)
SPU (40, 50, 75) 20' 12' 9"
SPU (50, 75, 100, 125) 30' 17' 9"'
SPU (100,125, 150, 175) 40' 22' 9"
SPU (125, 150, 175, 200) 50' 27' 9"
SPU (150, 175, 200) 60' 32' 9"
SPU (175, 200) 70' 37' 9"

SPU Dimensions - Bottom View SPU Dimensions - End View

Model BTU/HR Input Total Emitter Tube Length
20 FT. 30 FT. 40 FT. 50 FT. 60 FT. 70 FT.
SPU 40 40,000
SPU 50 50,000
SPU 75 75,000
SPU 100 100,000
SPU 125 125,000
SPU 150 150,000
SPU 175 175,000
SPU 200 200,000

*Model number is based on Btu/hr input (e.g., 100,000 Btu/hr), total emitter length (e.g., 40 feet) and control suffix for gas type (eg. natural gas-single stage-N5 or two stage-N7). For example, the model number for a straight tube single stage heater would be SPS100-40-N5 and for a U-tube heater would be SPU100-40-N5.

Tough Guy Option: All aluminized steel radiant tubes
For Tough Guy option the model number would be SPU100-40-TG-N5. Note: for Carwashes, Dairy Barns, Greenhouses, Swimming Pools, Waste Water Treatment Plants, and other high humidity / corrosive environments, Tough Guy with all aluminized tubes is recommended.

SPS & SPU Burner Box Dimensions

SIU, SPU U Bend Reflector Dimensions

SPU Supply Requirements

Gas Type Burner Pressure Supply Pressure Voltage Amps Ignition Type
MIN MAX
Natural 3.5" W.C. 5" W.C. 14" W.C. 120 VAC 60 Hz 2.4 Direct Spark
Propane 10" W.C. 11" W.C. 14" W.C. 120 VAC 60 Hz 2.4 Direct Spark

SPU Minimum Mounting Heights

Model Height at Horizontal Height at 45° Angle
SPU 40 10' 9'
SPU 50 11' 10'
SPU 75 13' 12'
SPU 100 14' 13'
SPU 125 14' 13'
SPU 150 15' 14'
SPU 175 16' 15'
SPU 200 18' 16'

SPU Minimum Mounting Heights

SPU Clearances to Combustibles

Model Side Ceiling* Below End (45°) Front (45°) Rear
SPU 40 22" 6" 52" 15" 40" 12"
SPU 50 22" 6" 56" 15" 48" 12"
SPU 75 22" 6" 60" 15" 52" 12"
SPU 100 28" 6" 70" ** 15" 58" 12"
SPU 125 28" 6" 76" ** 20" 66" 12"
SPU 150 34" 6" 81" ** 20" 70" 12"
SPU 175 38" 6" 86" ** 20" 75" 12"
SPU 200 42" 6" 93" ** 20" 80" 12"

* When used indirect vented, minimum clearance for Ceiling must be: 12″ for SPU 40-75, and 18″ for SPU 100-200. If optional corner and u-bend reflectors are not used, the clearance must be 18″.

** Maximum clearance below reduces by 50% once you are 25ft. downstream from the burner box.

SPU Clearances to Combustables

PDF Icon
Specifications
PDF Icon
Installation Manual
PDF Icon
Accessories

Additional information

Weight 2976 oz
Dimensions 1 × 1 × 1 in
Application

Commercial/Industrial

Tube

U-Shaped

Vacuum System

Push Through (positive pressure)

Gas Type

Natural Gas, Propane

menuchevron-down-circle
SPU50-30 50,000 BTU 30' Total Emitter Tube Length 'U' Shaped
SPU50-30 50,000 BTU 30' Total Emitter Tube Length 'U' Shaped
Original price was: $1,463.00.Current price is: $1,341.20.
Natural Gas
Propane
- +
0